The start cap is momentarily applied to the circuit then quickly disengaged.
Potential relay troubleshooting.
Whenever possible the model number on the old relay should be used when ordering a new relay.
All you have to do is touch the ends of the.
Potential relay operation and testing.
Troubleshooting of a potential relay can be done with an ohmmeter.
A simple ohmmeter is all that is needed to troubleshoot a potential relay.
I show the.
This video explains the terminal arrangement of a potential relay how to wire it up and how it works.
After taking all of the connecting wires off of the potential relay measure the resistance across the 1 and 2 terminals.
The resistance should read close to zero since there are normally closed contacts between terminals 1 and 2.
Potential starting relays consist of a high resistance coil and a set of normally closed contacts.
The coil is wired between terminals 2 and 5 with the contacts between terminals 1 and 2.
It s probably a bad potential relay.
When used with a run capacitor a 15 000 ohm to 18 000 ohm 2 w bleed resistor should be attached to the start capacitor to prevent possible arcing when the relay contacts open.
The above procedure simply mimics the action of the potential relay.
Remember short out the start cap used above.
I ve used this procedure many times.
The relay does the same thing.
My paperback and e book.
A simple ohmmeter is all that is needed to troubleshoot a potential relay.